Price Low Voltage 4 Core 95mm XLPE/PVC Insualted Armoured Submarine Power Cable

Model NO.: 8mm2, 35mm2, 50mm2, 95 mm2
Material Shape: Round Wire
Range of Application: Refractory
Certification: ISO9001, CE, CCC
Brand: Jytop
Cores Number: 2 Core, 3 Core, 4 Core, 5 Core
Standards: ASTM IEC DIN VDE...
Conductor: Aluminum Stranded
Color: Black
Trademark: JYTOP
Transport Package: Drum or Reel
Specification: based on ASTM or IEC or BS or NF standards
Origin: Zhengzhou, China
HS Code: 8544492100
Model NO.: 8mm2, 35mm2, 50mm2, 95 mm2
Material Shape: Round Wire
Range of Application: Refractory
Certification: ISO9001, CE, CCC
Brand: Jytop
Cores Number: 2 Core, 3 Core, 4 Core, 5 Core
Standards: ASTM IEC DIN VDE...
Conductor: Aluminum Stranded
Color: Black
Trademark: JYTOP
Transport Package: Drum or Reel
Specification: based on ASTM or IEC or BS or NF standards
Origin: Zhengzhou, China
HS Code: 8544492100
price low voltage 4 core 95mm XLPE/PVC insualted armoured submarine power cable
 

Standard:

IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.

The Rated Voltage(kv):

1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

Application:

Power cable are most suitable for direct burial or for installation on trays or ducts,  Where there is
a risk of mechanical damage, armoured cables should be used.

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1x4 2.3 0.7 1 0.8 1.8 10.9
1x6 2.8 0.7 1 0.8 1.8 11.4
1x10 3.6 0.7 1 0.8 1.8 12.2
1x16 4.5 0.7 1 0.8 1.8 13.1
1x25 5.6 0.9 1 0.8 1.8 14.6
1x35 6.7 0.9 1 1.25 1.8 16.6
1x50 8 1 1 1.25 1.8 18.1
1x70 9.4 1.1 1 1.25 1.8 19.7
1x95 11 1.1 1 1.6 1.8 22
1x120 12.4 1.2 1 1.6 1.8 23.6
1x150 13.8 1.4 1 1.6 1.8 25.4
1x185 15.3 1.6 1 1.6 1.8 27.4
1x240 17.5 1.7 1 1.6 1.9 29.9
1x300 19.5 1.8 1 2 2 33.1
1x400 22.6 2 1.2 2 2.2 37.3
1x500 25.2 2.2 1.2 2 2.3 40.5

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x1.5 1.4 0.7 1 0.8 1.8 12.8
2x2.5 1.8 0.7 1 0.8 1.8 13.6
2x4 2.3 0.7 1 0.8 1.8 14.6
2x6 2.8 0.7 1 1.25 1.8 16.5
2x10 3.6 0.7 1 1.25 1.8 18.1
2x16 4.5 0.7 1 1.25 1.8 19.9
2x25 5.6 0.9 1 1.6 1.8 23.6
2x35 6.7 0.9 1 1.6 1.8 25.8
2x50 8 1 1 1.6 1.9 29
2x70 9.4 1.1 1 2 2 .3 3.2
2x95 11 1.1 1.2 2.1 3 7.1
2x120 12.4 1.2 1.2 2 2.3 40.5
2x150 13.8 1.4 1.2 2.5 2.4 45.4
2x185 15.3 1.6 1.4 2.5 20.6 49.9
2x240 17.5 1.7 1.4 2.5 20.7 55.1
2x300 19.5 1.8 1.6 2.5 20.9 60.2
2x400 22.6 2 1.6 2.5 30.1 67.7

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3x1.5 1.4 0.7 1 0.8 1.8 13.2
3x2.5 1.8 0.7 1 0.8 1.8 14.1
3x4 2.3 0.7 1 0.8 1.8 15.2
3x6 2.8 0.7 1 1.25 1.8 17.1
3x10 3.6 0.7 1 1.25 1.8 18.9
3x16 4.5 0.7 1 1.25 1.8 20.8
3x25 5.6 0.9 1 1.6 1.8 24.7
3x35 6.7 0.9 1 1.6 1.8 27.2
3x50 8 1 1 1.6 1.9 30.6
3x70 9.4 1.1 1 2 2.1 35.2
3x95 11 1.1 1.2 2 2.2 39.3
3x120 12.4 1.2 1.2 2 2.3 43
3x150 13.8 1.4 1.4 2.5 2.5 48.6
3x185 15.3 1.6 1.4 2.5 2.7 53
3x240 17.5 1.7 1.4 2.5 2.8 58.5
3x300 19.5 1.8 1.6 2.5 3 64
3x400 22.6 2 1.6 3.15 3.3 73.5

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3x120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3x150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3x185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3x240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3x300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4x1.5 1.4 0.7 1 0.8 1.8 14
4x2.5 1.8 0.7 1 0.8 1.8 14.9
4x4 2.3 0.7 1 1.25 1.8 17
4x6 2.8 0.7 1 1.25 1.8 18.2
4x10 3.6 0.7 1 1.25 1.8 20.2
4x16 4.5 0.7 1 1.6 1.8 23
4x25 5.6 0.9 1 1.6 1.8 26.7
4x35 6.7 0.9 1 1.6 1.9 29.5
4x50 8 1 1 2 2.1 34.2
4x70 9.4 1.1 1.2 2 2.2 38.8
4x95 11 1.1 1.2 2 2.3 42.9
4x120 12.4 1.2 1.4 2.5 2.5 48.6
4x150 13.8 1.4 1.4 2.5 2.7 53.2
4x185 15.3 1.6 1.4 2.5 2.8 58.1
4x240 17.5 1.7 1.6 2.5 3.1 64.8
4x300 19.5 1.8 1.6 2.5 3.2 70.4
4x400 22.6 2 1.8 3.15 3.6 81.3

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
Price Low Voltage 4 Core 95mm XLPE/PVC Insualted Armoured Submarine Power Cable
 

price low voltage 4 core 95mm XLPE/PVC insualted armoured submarine power cable
 

Standard:

IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.

The Rated Voltage(kv):

1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

Application:

Power cable are most suitable for direct burial or for installation on trays or ducts,  Where there is
a risk of mechanical damage, armoured cables should be used.

TYPE

NAME

Main Application

CU core

AL core

 

 

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1x4 2.3 0.7 1 0.8 1.8 10.9
1x6 2.8 0.7 1 0.8 1.8 11.4
1x10 3.6 0.7 1 0.8 1.8 12.2
1x16 4.5 0.7 1 0.8 1.8 13.1
1x25 5.6 0.9 1 0.8 1.8 14.6
1x35 6.7 0.9 1 1.25 1.8 16.6
1x50 8 1 1 1.25 1.8 18.1
1x70 9.4 1.1 1 1.25 1.8 19.7
1x95 11 1.1 1 1.6 1.8 22
1x120 12.4 1.2 1 1.6 1.8 23.6
1x150 13.8 1.4 1 1.6 1.8 25.4
1x185 15.3 1.6 1 1.6 1.8 27.4
1x240 17.5 1.7 1 1.6 1.9 29.9
1x300 19.5 1.8 1 2 2 33.1
1x400 22.6 2 1.2 2 2.2 37.3
1x500 25.2 2.2 1.2 2 2.3 40.5

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x1.5 1.4 0.7 1 0.8 1.8 12.8
2x2.5 1.8 0.7 1 0.8 1.8 13.6
2x4 2.3 0.7 1 0.8 1.8 14.6
2x6 2.8 0.7 1 1.25 1.8 16.5
2x10 3.6 0.7 1 1.25 1.8 18.1
2x16 4.5 0.7 1 1.25 1.8 19.9
2x25 5.6 0.9 1 1.6 1.8 23.6
2x35 6.7 0.9 1 1.6 1.8 25.8
2x50 8 1 1 1.6 1.9 29
2x70 9.4 1.1 1 2 2 .3 3.2
2x95 11 1.1 1.2 2.1 3 7.1
2x120 12.4 1.2 1.2 2 2.3 40.5
2x150 13.8 1.4 1.2 2.5 2.4 45.4
2x185 15.3 1.6 1.4 2.5 20.6 49.9
2x240 17.5 1.7 1.4 2.5 20.7 55.1
2x300 19.5 1.8 1.6 2.5 20.9 60.2
2x400 22.6 2 1.6 2.5 30.1 67.7

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3x1.5 1.4 0.7 1 0.8 1.8 13.2
3x2.5 1.8 0.7 1 0.8 1.8 14.1
3x4 2.3 0.7 1 0.8 1.8 15.2
3x6 2.8 0.7 1 1.25 1.8 17.1
3x10 3.6 0.7 1 1.25 1.8 18.9
3x16 4.5 0.7 1 1.25 1.8 20.8
3x25 5.6 0.9 1 1.6 1.8 24.7
3x35 6.7 0.9 1 1.6 1.8 27.2
3x50 8 1 1 1.6 1.9 30.6
3x70 9.4 1.1 1 2 2.1 35.2
3x95 11 1.1 1.2 2 2.2 39.3
3x120 12.4 1.2 1.2 2 2.3 43
3x150 13.8 1.4 1.4 2.5 2.5 48.6
3x185 15.3 1.6 1.4 2.5 2.7 53
3x240 17.5 1.7 1.4 2.5 2.8 58.5
3x300 19.5 1.8 1.6 2.5 3 64
3x400 22.6 2 1.6 3.15 3.3 73.5

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3x120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3x150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3x185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3x240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3x300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4x1.5 1.4 0.7 1 0.8 1.8 14
4x2.5 1.8 0.7 1 0.8 1.8 14.9
4x4 2.3 0.7 1 1.25 1.8 17
4x6 2.8 0.7 1 1.25 1.8 18.2
4x10 3.6 0.7 1 1.25 1.8 20.2
4x16 4.5 0.7 1 1.6 1.8 23
4x25 5.6 0.9 1 1.6 1.8 26.7
4x35 6.7 0.9 1 1.6 1.9 29.5
4x50 8 1 1 2 2.1 34.2
4x70 9.4 1.1 1.2 2 2.2 38.8
4x95 11 1.1 1.2 2 2.3 42.9
4x120 12.4 1.2 1.4 2.5 2.5 48.6
4x150 13.8 1.4 1.4 2.5 2.7 53.2
4x185 15.3 1.6 1.4 2.5 2.8 58.1
4x240 17.5 1.7 1.6 2.5 3.1 64.8
4x300 19.5 1.8 1.6 2.5 3.2 70.4
4x400 22.6 2 1.8 3.15 3.6 81.3

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
Price Low Voltage 4 Core 95mm XLPE/PVC Insualted Armoured Submarine Power Cable
 

Automation Light Curtain

This Automation curtain is specially designed for automation industry. SDKELI LSC2 light curtain is designed for automation field, with small size, compact structure and strong anti-interference ability, and the product meets IEC 61496-2 standards. The automatic light curtain is with reliable quality and very competitive price. It has been used in many factories and has replaced curtains from Sick, Omron, Banner, Keyence, etc.

Automatic Light Curtain,Laser Light Curtain,Automation Light Beam Sensor,Automatic Infrared Beam Sensor,Infrared Beam Curttain Sensor,Infrared Beam Sensor

Jining KeLi Photoelectronic Industrial Co.,Ltd , https://www.sdkelien.com

Posted on